fbpx

Spintly

Select your region

USA
India

INTSALLATION GUIDE :

INSTALLATION GUIDE

Spintly QR Reader

Model No : SQR-012

Spintly QR reader with it’s elegant design provides seamless user experience that allows QR based access and also allows users to unlock doors with their smartphones and cards.

Spintly QR reader with it’s elegant design provides seamless user experience that allows QR based access and also allows users to unlock doors with their smartphones and cards.

1. Product Features and Specifications

1.1. Features

  • Wireless BLE Mesh Networking
  • Easy to Install and Set-up
  • QR based access
  • Cloud based platform
  • Smartphone based access
  • Card based access

1.2. Electrical Specifications

  • Power source: 12V / 24V DC Input
  • Power consumption: 2.4W max at 12V

1.1. Features

  • Wireless BLE Mesh Networking
  • Easy to Install and Set-up
  • QR based access
  • Cloud based platform
  • Smartphone based access
  • Card based access

1.2. Electrical Specifications

  • Power source: 12V / 24V DC Input
  • Power consumption: 2.4W max at 12V

2. Mechanical Dimensions

3. Mounting Instructions :

Below images illustrates the mounting of QR module and reader on the pole

Step 1. Above image show reader, QR module ready to be mounted on pole

Step 2. Assemble the QR module and reader in the top pole housing with the adhesive tape

Step 3. Once the devices are assembled in top housing, pass the pigtail through the opening in the pole as shown in above image

Step 4. Place the top pole housing on the bottom one as shown in above image

Step 5. Close the pole with the help of screws as shown in above image

4. Wiring Instructions

4.1. Pigtail color code

QR reader is equipped with a 8 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color code.

The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.

4.2. Configuration 1 : Standalone Spintly Reader

Installation type : Entry Reader and REX

4.3. Configuration 2 : Spintly Entry - Exit reader

Installation type : Entry-Exit

  • In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly for GND wires (ground).
  • The locking mechanism (Strike lock or Magnetic lock) should be connected to Exit reader
  • The sensor inputs (REX and Door sensor) should be connected to Exit reader

Get in touch