INTSALLATION GUIDE :

INSTALLATION GUIDE

NUOS 1

NUOS-1

NUOS-1 is a single door controller.
It has native OSDP support which provides the highest level of security and reliability. It is designed to be mounted on the secured side of a door, and configurable to make all access control decisions.

Spintly UNO Reader with it’s elegant design provides seamless user experience that allows users to unlock doors with their smartphones.

NUOS 1

1. Product Features and Specifications

1.1. Features

  • NUOS-1 supports 2 modes of configuration
       1.     Standalone Controller mode
       2.    Controller + Reader mode
  • Compact design
  • BLE Mesh connectivity to Gateway
  • Selectable Dry/Wet relay contact
  • Cloud based access management
  • Local storage of configurations
  • Over-the-air firmware update support

1.2. Electrical Specifications

  • Power source: 12V / 24V DC Input
  • Power consumption: 2.4W max at 12V

1.1. Features

  • NUOS-1 supports 2 modes of configuration
       1.     Standalone Controller mode
       2.    Controller + Reader mode
  • Compact design
  • BLE Mesh connectivity to Gateway
  • Selectable Dry/Wet relay contact
  • Cloud based access management
  • Local storage of configurations
  • Over-the-air firmware update support

1.2. Electrical Specifications

  • Power source: 12V / 24V DC Input
  • Power consumption: 2.4W max at 12V

2. Mechanical Dimensions

  • Length = 124.5 mm
  • Width = 67.5 mm
  • Depth = 22.5 mm

3. Mounting Instructions :

Step 1. Pick out the connectors (2pin-A, 4pin-B, 6pin-C) provided in the box as shown in below image

Step 2. Connection diagram and configurations supported:

It can support 2 modes of configuration. The connection of wires will differ based on the selected configuration.

3.1. Configuration 1 : Standalone Spintly Controller

Installation type : Entry Reader and REX

To ensure proper setup, follow the connection diagram (Fig 1.1 below) and screw in the wires into A, B, C (using screw driver provided in box).
Note : Observe the orientation of A, B and C while screwing in the wires. The screw terminal should be facing the user.

3.2. Configuration 2 : Spintly Reader with Controller

Installation type : Reader + Controller

  • Controller side – Toggle the switch to WET position to enable lock power on common terminal of relay (as shown below in Fig 3.2.1)

 

  • Reader side – Make sure the interface switch is toggled to “O” (OSDP) position as instructed previously. Refer Reader manual – section 3 – step 2.
  • These 4 wires should be connected from Reader to Controller
  • Power wires — V+ and GND
    Communication wires — Connect RS485 A and RS485 B (refer the Reader manual for color code) to the A and B terminal of the controller respectively. Refer controller manual for more details.
  • The locking mechanism (Strike lock or Magnetic lock) should be connected to Controller
  • The sensor inputs (REX and Door sensor) should be connected to controller

Step 3. Plug in the connectors A, B and C as shown in the below image

Step 4. Mounting of device on wall
Pre-drill the mounting locations using “Drill Template” provided in the box.
Mount the unit on the wall with the help of wall plugs and screws (2 qty) as shown above.