AURA – The Next-Gen Reader. Launching Soon

Learn More About AURA
Connection guide

Spintly NUOS 1-Door Controller (SNU-012)

Spintly NUOS is a single door controller with highest level of security and reliability.

Contents
Spintly NUOS 1-Door Controller

1. Product Features and Specifications

1.1. Features

  • NUOS 1-Door Controller supports 2 modes of configuration 1. Standalone Controller mode 2. Controller + Reader mode
  • Cloud based access management
  • Wall mountable
  • Encrypted communication between Spintly reader to controller using AES-128
  • Local storage of configurations

1.2. Electrical Specifications

  • Power source: 9V – 30V DC Input
  • Power consumption: 2.4W max at 12V
  • NUOS 1-Door Controller supports 2 modes of configuration 1. Standalone Controller mode 2. Controller + Reader mode
  • Cloud based access management
  • Wall mountable
  • Encrypted communication between Spintly reader to controller using AES-128
  • Local storage of configurations
  • Power source: 9V – 30V DC Input
  • Power consumption: 2.4W max at 12V

2. Mechanical Dimensions

Spintly NUOS 1-Door Controller (SNU-012): diagram 1
  • Length = 100 mm
  • Width = 157 mm
  • Depth = 52 mm
  • Length = 100 mm
  • Width = 157 mm
  • Depth = 52 mm

3. Mounting Instructions

Spintly NUOS 1-Door Controller (SNU-012): diagram 2

Fig 3.1

Step 1. Pick out the unit from the packaging box.

Spintly NUOS 1-Door Controller (SNU-012): diagram 3

Fig 3.2

Step 2. Unscrew the 4 screws as shown in the image above to open the enclosure.

Spintly NUOS 1-Door Controller (SNU-012): diagram 4

Fig 3.3

Step 3. Break in the rubber grommet (attached to Top enclosure lid) with some sharp object.

Spintly NUOS 1-Door Controller (SNU-012): diagram 5

Fig 3.4

Step 4. Pass the required no of wires through opening (based on configuration) as represented in above image.

Spintly NUOS 1-Door Controller (SNU-012): diagram 6

Fig 3.5

Step 5. Refer to section 4 below for detailed connection diagram.

Once the configuration mode is known, pick the Pluggable terminal connector provided in the box.

Observe the orientation of connector. The screw terminal should be facing the user.

Now follow the connection diagram (as per the section 4) and screw in the wires to the pluggable terminal connector with the help of screw driver provided in box.

Spintly NUOS 1-Door Controller (SNU-012): diagram 7

Fig 3.6

Step 6. Verify all the connections done before moving to next step.

• Make sure all the cables are passed through “Top enclosure Lid” (as shown in above image)

• Verify the connection and the sequence of wires plugged into pluggable terminal connector.

WARNING : The wiring done in reverse orientation can damage the device!

Spintly NUOS 1-Door Controller (SNU-012): diagram 8

Fig 3.7

Step 7. Plug in the pluggable terminal connector into device terminal connector.

Spintly NUOS 1-Door Controller (SNU-012): diagram 9

Fig 3.8

Step 8. Close the enclosure with the help of screws as shown in above image.

Spintly NUOS 1-Door Controller (SNU-012): diagram 10

Fig 3.9

Step 9.

Mounting of device on wall:

Pick out below items provided in the box • NUOS Drill template • Wall plugs • Mounting screws (ISO #6, 25mmL, PAN (+))

Use the drill template to drill two holes on the wall.

Insert wall plugs, and secure the enclosure with two screws as shown in above image.

4. Configurations

It can support 2 modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below and follow the specified wiring instructions corresponding to your chosen mode.

4.1 Configuration 1 : Standalone Spintly Controller

Spintly NUOS 1-Door Controller (SNU-012): diagram 11

Fig 4.1

4.2 Configuration 2 : Spintly Reader with Controller

Installation type : New install (OSDP enabled)

This controller can be installed with below models of UNO

  • SU-016
  • SU-013(V2)
Spintly NUOS 1-Door Controller (SNU-012): diagram 12
Spintly NUOS 1-Door Controller (SNU-012): diagram 13
  • Make sure the interface switch on reader is toggled to “O” (OSDP) position (for Model No : SU-016)
  • Below mentioned 4 wires should be connected from Reader to the respective terminal of Controller (as shown in below Fig 4.2) Power wires — VIN and GND Communication wires — Connect RS485 A and RS485 B (refer the color code shown in the above table 4.2) to the A and B terminal of the controller respectively. Refer reader manual for more details.
  • Connect the locking mechanism and sensor inputs (Door sensor and REX) to controller.
Spintly NUOS 1-Door Controller (SNU-012): diagram 14

Fig 4.2

Book a demo

Need Help with an Installation?

Our support team helps installers with wiring, configuration and commissioning.

  • A Spintly expert gets back to you within 24 hours
  • A site walkthrough and a tailored quote

Prefer email? sales@spintly.com

Please contact me at

Chat with us

Download the Datasheet

Fill out the form below and the datasheet opens straight away.

Need Help Finding the Solution You're Looking For?

Manage credentials in seconds and open doors remotely, all while overseeing every site with ease. At Spintly, we're leading the way in cloud-based physical security.

Trusted by Industry Leaders

  • Anarock
  • Brigade Group
  • Godrej
  • JLL
  • Tata Consumer Products
  • K Raheja Corp

Fill out the form below and our expert team will reach out to you.

Please contact me at