AURA – The Next-Gen Reader. Launching Soon

Learn More About AURA
Installation guide

Spintly 3-in-1 Reader (SF-012)

Installation guide for the Spintly 3-in-1 Reader: mounting, wiring and configuration, step by step.

Contents
Spintly 3-in-1 Reader

Spintly 3-IN-1

Spintly 3-in-1 access control with its elegant design provides a Flexible Modular and Scalable approach to upgrade your regular doors to smart doors. A smart efficient Fingerprint, Smartphone and NFC cards based solution to manage your access.

1. Product Features and Specifications

1.1. Features

  • Wireless BLE Mesh Networking
  • Easy to Install and Set-up
  • Fingerprint based access
  • Fast Identification speed
  • Cloud based platform
  • Smartphone based access
  • Card based access

1.2. Electrical Specifications

  • Power source: 12V/24V DC Input
  • Power consumption: 2.4W max at 12V

2. Mechanical Dimensions

Spintly 3-in-1 Reader (SF-012): diagram 1

Fig. 2.1

3. Mounting Instructions

Spintly 3-in-1 Reader (SF-012): diagram 2

Fig. 3.1

Step 1. Pre-drill the mounting locations using Drill Template provided in the box.

Step 2. Insert the wall plugs (5 Qty) and secure the back plate using the screws provided(5 Qty)

Step 3. Strip and connect the wires as per the pigtail color code and connection diagram. Refer Fig 4.2 under Wiring Instructions.

Step 4. Install the main unit using M3x8mm screws(2 qty)

4. Wiring Instructions

4.1. Pigtail Color Code

3-in-1 reader is equipped with a 10 core pigtail required during the wiring process. The table below describes the signal names along with their corresponding color code.

Spintly 3-in-1 Reader (SF-012): diagram 3

Fig. 4.1.1

The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.

4.2. Configuration 1 : Standalone Spintly Reader

Spintly 3-in-1 Reader (SF-012): diagram 4

Fig. 4.2.1

4.3. Configuration 2 : Spintly Entry with Exit Reader

Spintly 3-in-1 Reader (SF-012): diagram 5

Fig. 4.3.1

  • In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly for GND wires (ground).
  • Short VIN wire to COMMON wire of Entry Reader
  • Short NC (in case of mag lock) wire of Entry Reader to COMMON wire of Exit Reader
  • Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Exit Reader
  • The sensor inputs,REX should be connected to Exit readerDoor Sensor – To enable DOTL, please connect the door sensor to the Entry Reader (as sown in above Fig 4.3.1)
  • Door break-in feature is not available under this configuration.
Book a demo

Need Help with an Installation?

Our support team helps installers with wiring, configuration and commissioning.

  • A Spintly expert gets back to you within 24 hours
  • A site walkthrough and a tailored quote

Prefer email? sales@spintly.com

Please contact me at

Chat with us

Download the Datasheet

Fill out the form below and the datasheet opens straight away.

Need Help Finding the Solution You're Looking For?

Manage credentials in seconds and open doors remotely, all while overseeing every site with ease. At Spintly, we're leading the way in cloud-based physical security.

Trusted by Industry Leaders

  • Anarock
  • Brigade Group
  • Godrej
  • JLL
  • Tata Consumer Products
  • K Raheja Corp

Fill out the form below and our expert team will reach out to you.

Please contact me at