INSTALLATION GUIDE :
INSTALLATION GUIDE
Spintly UNO-WO-LF
Model No : SU-017
Spintly UNO-WO-LF Reader with it’s elegant design provides seamless user experience that allows users to unlock doors with their smartphones.
Spintly UNO-WO-LF Reader with it’s elegant design provides seamless user experience that allows users to unlock doors with their smartphones.
1. Product Features and Specifications
1.1. Features
- BLE Mesh connectivity to Gateway
- Wide Input operating voltage range
- Retrofit with legacy controllers over Wiegand or OSDP
- Tamper detection
- Cloud based access management
- Adjustable operational distance for Mobile credential access
- Over-the-air firmware update support
1.2. Electrical Specifications
- Power source: 12V / 24V DC Input
- Power consumption: 2.4W max at 12V
1.1. Features
- BLE Mesh connectivity to Gateway
- Wide Input operating voltage range
- Retrofit with legacy controllers over Wiegand or OSDP
- Tamper detection
- Cloud based access management
- Adjustable operational distance for Mobile credential access
- Over-the-air firmware update support
1.2. Electrical Specifications
- Power source: 12V / 24V DC Input
- Power consumption: 2.4W max at 12V
3. Mounting Instructions :
4. Wiring Instructions :
4.1. Pigtail color code
UNO-WO-LF reader is equipped with a 10 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color code.
The reader supports various modes of configuration. The connection of wires will differ based on the selected configuration. To ensure proper setup and functionality, refer to the configurations listed below.
4.2. Configuration 1 : Standalone Spintly Reader
Installation type : Entry Reader and REX
4.3. Configuration 2 : Spintly Entry with Exit Reader
Installation type : Entry-Exit (OSDP enabled)
- In this mode, both the entry and exit Spintly readers will share the same power lines. Connect together the VIN wires of both the readers. Similarly for GND wires (ground).
- Short VIN wire to COMMON wire of Entry Reader
- Short NC (in case of mag lock) wire of Entry Reader to COMMON wire of Exit Reader
- Connect the locking mechanism (Strike lock or Magnetic lock) to NC (in case of mag lock) wire of Exit Reader
- The sensor inputs (REX and Door sensor) should be connected to Exit reader
4.4. Configuration 3 : Spintly Reader with Controller
Installation type : New install (OSDP enabled)
- Make sure the interface switch on reader is toggled to “O” (OSDP) position as instructed previously. Refer to section 3 – step 2.
- These 4 wires should be connected from Reader to Controller
- Power wires — V+ and GND
- Communication wires — Connect RS485 A and RS485 B (refer the color code shown in the above table) to the A and B terminal of the controller respectively. Refer controller
manual for more details.
4.5. Configuration 4 : Spintly Reader with Wiegand Controller
Installation type : Retrofit (Wiegand enabled)
- Make sure the interface switch is toggled to “W” (Wiegand) position as instructed previosuly. Refer to section 3 – step 2.
- Below mentioned 5 wires should be connected from Reader to Wiegand controller (as shown in below image 4.5.1)
- Power wires — V+ and GND
- Communication wires — DATA0, DATA1, and GLED (refer the color code shown in above table) to the respective terminals of Wiegand controller.
For configuration 3 and 4 :
- The locking mechanism (Strike lock or Magnetic lock) should be connected to Controller
- The sensor inputs (REX and Door sensor) should be connected to controller