UNO-W, 10 core pigtail color code

UNO-W devices are equipped with a 10 core pigtail required during the connection process. The table below describes the signal names along with their corresponding color codes, providing guidance for the wiring of UNO-W.

Entry device wiring connection

Entry and Exit device wiring connection

For Entry-Exit connection:

  • Connect VCC and GND of entry and exit reader together
  • The locking mechanism (Strike lock or Magnetic lock) should be connected to NO or NC respectively of Exit reader
  • Also sensor inputs like REX and Door sensor should be connected to Exit reader

Entry and legacy controller connection

Installation type : Retrofit

  • Connect VCC and GND of entry reader and controller together
  • Connect the reader wires – DATA0, DATA1, and GLED as per color code shown in table to the respective terminals of the controller.

DATA 0 : GREEN
DATA 1 : WHITE
GLED : ORANGE

  • The locking mechanism (Strike lock or Magnetic lock) should be connected to Controller
  • Also sensor inputs like REX and Door sensor should be connected to the controller