INSTALLATION GUIDE :

INSTALLATION GUIDE

MESH-IO

Model No : SMI-01

The Spintly Mesh-IO provides a scalable approach to increase the range of your BLE mesh-enabled IoT network. It is capable of interfacing with Fire Alarm panels, remote sensors monitoring via additional I/O support, providing a BLE Mesh communication extension to legacy hardware.

The Spintly Mesh-IO provides a scalable approach to increase the range of your BLE mesh-enabled IoT network. It is capable of interfacing with Fire Alarm panels, remote sensors monitoring via additional I/O support, providing a BLE Mesh communication extension to legacy hardware.

1. Product Features and Specifications

1.1. Features

  • BLE Mesh connectivity to Gateway
  • BLE Mesh Networking
  • Wide Input operating voltage
  • BLE Mesh range extension
  • Integration with 3rd party devices

1.2. Electrical Specifications

  • Voltage ratings : 5V/12V DC
  • Power consumption : 0.75mW max at 5V

2. Mechanical Dimensions

3. Mounting Instructions :

Step 1. Mounting of device on wall

  • Pre-drill the mounting locations (A and B) using drill template provided in the box
  • Mount it on the wall with the help of wall plugs and screws (4 qty) as shown below.

Fig 3.1

Step 2. Power the device using the adapter provided in the box

4. Mesh IO Pinout:

3.1. Configuration 1 : Standalone Spintly Controller

To ensure proper setup, follow the connection diagram (Fig 3.1.1 below) and screw in the wires into A, B, C (using screw driver provided in box)
Note : Observe the orientation of A, B and C while screwing in the wires. The screw terminal should be facing the user.

3.2. Configuration 2 : Spintly Reader + Controller

  • Reader side – Make sure the interface switch is toggled to “O” (OSDP) position as instructed previously. Refer Reader manual – section 3 – step 2.
  • These 4 wires should be connected from Reader to Controller
    • Power wires — V+ and GND
    • Communication wires — Connect RS485 A and RS485 B (refer the Reader manual for color code) to the A and B terminal of the controller respectively. Refer controller manual for more details.
  • The locking mechanism (Strike lock or Magnetic lock) should be connected to the Controller
  • The sensor inputs (REX and Door sensor) should be connected to controller

Step 3. Plug in the connectors A, B and C as shown in the below image

Step 4. Mounting of device on wall

Pre-drill the mounting locations using “Drill Template” provided in the box. Mount the unit on the wall with the help of wall plugs and screws (2 qty) as shown above.